Functions, characteristics
The HX-101 heat exchanger unit is a high efficiency heat exchanger unit employing Lintecfs liquid vaporizer unit construction. In order to vaporize liquids it is necessary to apply heat efficiently to the liquids. An efficient vaporization unit can be used without major modification as an efficient heat exchange unit. Because the HX-101 employs this vaporization unit construction, high efficiency and compactness have been realized.
In addition, due to the use of a clean construction employing 316L stainless steel for gas contact surfaces, this device can be used not only for exhaust lines but also process chamber inlets, as well as the heating of a wide range of process and vaporization unit carrier gases. As a safety mechanism a thermal switch is built in as standard and this can be used as an alarm signal in case of overheating. Please use this device for the heating of all kinds of gases. The HX-101 heat exchanger unit is divided into two types, the HX-101-L100 and the HX-101-L300, depending on the capacity of the heaters used. The L100 can heat gas flow rates of up to approximately 100 litres per minute, while the L300 is capable of heating gas flow rates of up to 300 litres per minute. For smaller flow rate applications Lintec has available the HX-10A which is capable of heating gas flow rates of up to 50 litres per minute. In addition, we also have available control units including temperature control and flow rate control units as well as alarm functions.

>>HX-10A(small flow rate heat exchanger)






Download of the PDF catalog is available.
Get the Acrobat Reader if you need it.
Acrobat Reader download
•HX-101 heat exchanger unit
PDF>>Catalog Data (480kB)
>>Contact us.
Specifications

Product name

Heat Exchanger

Model name

HX-101-L100

HX-101-L300

Maximum operating pressure

300kPa

Withstand pressure

1MPa

Operating temp.

300°CMax

250°CMax

Leak integrity

Less than 1x10-11Pa・m3/sec(He)

Materials exposed to gas

SS-316L

Fittings

Inlet: 12.7mmVCR male Outlet: 12.7mmVCR female

Heater power
requirements

Outer block 120V 400W
Inner block 120V 300W

Outer block 240V 1200W
Inner block 240V 900W

Thermocouple

K type JIS 0.75grade (2)

Thermal switch

Open above 350}10°C AC110/220V 300W

Pressure drop

9.8kPa (100L/min)

30kPa (300L/min)

Weight

5.5kg


>>DXF format CAD data (3353K)
Dimensions